Skip to main content
Log in

Pediatric Anesthesia Monitoring with the Help of EEG and ECG

  • Published:
Acta Biotheoretica Aims and scope Submit manuscript

Abstract

This paper presents research regarding the monitoring of the brain and the adequacy of anesthesia during surgery. Particular variables are derived from EEG and ECG signals and are correlated to anesthetic gas (sevoflurane) concentration, in pediatric anesthesia. The methods used for parameter extraction are based on change detection theory and time-frequency representation. Preliminary results show that the expired anesthetic gas concentration modulates both the heart rate variability and the duration of the burst suppression. Monitors of the central nervous system and autonomic nervous system activities can be expected to be based on these variables.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  • Akselrod, S., D. Gordon, F. Ubel, D. Shannon, A. Berger and R. Cohen (1981). Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat to beat cardiovascular control. Science 213: 220.

    Google Scholar 

  • Basseville, M. and I. Nikiforov (1993). Detection of abrupt changes, Theory and application. Prentice-Halle, Englewood Cliffs, NJ.

    Google Scholar 

  • Bloom, M.J. (1997). EEG monitoring: intraoperative application. Anesthesiology clinics of North America. 15: 551–571.

    Google Scholar 

  • Deutschman, C.S., A.P. Harris and L.A. Fleisher (1994). Changes in heart rate variability under propofol anesthesia: a possible explanation for propofol induced bradycardia. Anesthesia Analgesia 79: 373–377.

    Google Scholar 

  • Donchin, Y., J.M. Feld and S.W. Porges (1985). Respiratory sinus arrhythmia during recovery from isoflurane-nitrous oxide anesthesia. Anesthesia Analgesia 64: 811–815.

    Google Scholar 

  • Drader, K.S. and I.A. Herrick (1997). Carotid endarterectomy: monitoring and its effect on outcome. Anesthesiology clinics of North America 15: 613–628.

    Google Scholar 

  • Gajraj, R.J., M. Doi, H. Mantzonidis and G.N.C. Kenny (1998). Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness. British Journal of Anesthesia 80: 46–52.

    Google Scholar 

  • Galletly, D.C., A.M. Westenberg, B.J. Robinson and T. Corfiatis (1998). Effect of halothane, isoflurane and fentanyl on spectral components of heart rate variability. British Journal of Anaesthesia 80: 72–77.

    Google Scholar 

  • Gauvrit, H., G. Carrault, P. Pladys, E. Wodey and F. Carré (1998). Monitoring of heart rate during paediatric anesthesia, Proc. CIC, 1998.

  • Gritzali, F. (1988). Towards a generalized scheme for QRS detection in ECG waveforms. Signal Processing 15: 183–192.

    Google Scholar 

  • Hall, J.D. and G.G. Lockwood (1998). Bispectral index: comparison of two montages. British Journal of Anesthesia 80: 342–344.

    Google Scholar 

  • Huowg, J.W., Ying-Ying Lu, A. Nayak and R.J. Roy (1999). Depth of anesthesia estimation and control IEEE-TBME (Transaction in Biomedical Engineering) 46: 71–81.

    Google Scholar 

  • IBIS (1997). Improved Monitoring for Brain Dysfunction in Intensive Care and Surgery. EC contract No. BMH4-97-2570.

  • Ireland, N., J. Meagher, J.W. Sleigh and J.D. Henderson (1996). Heart rate variability in patients recovering from general anaesthesia. British Journal of Anaesthesia 76: 57–62.

    Google Scholar 

  • Kato, M., T. Komatsu, T. Kimura, F. Sugiyama, K. Nakashima and Y. Shimada (1992). Spectral analysis of heart rate variability during isoflurane anesthesia. Anesthesiology 77: 669–674.

    Google Scholar 

  • Kawamoto, M., K. Kaneko, K. Hardian and O. Yuge (1994). Heart rate variability during artificial ventilation and apnea in brain damaged rabbits. American Journal of Physiology 6: 271; H410.

    Google Scholar 

  • Khalil, M. and J. Duchêne (1999) Detection and classification of multiple events in piecewise stationary signals: comparison between autoregressive and multiscale approaches. Signal Processing 75: 239–252.

    Google Scholar 

  • Langford, R.M. (1996). Clinical applications of cerebral monitoring. Computer methods and programs in biomedicine. 51: 29–33.

    Google Scholar 

  • Mahla, M.E. (1997). The electroencephalogram in operating room. Seminar in anesthesia, 16: pp. 3–13.

    Google Scholar 

  • Malliani, A., M. Pagani, F. Lombardi and S. Cerutti (1991). Cardiovascular neural regulation explored in the frequency domain. Circulation 84: 482–92.

    Google Scholar 

  • Mazerolles, M., J.M. Senard, P. Verwaerde, M.A. Tran, J.L. Montastruc, C. Virenque and P. Montastruc (1996). Effects of pentobarbital and etomidate on plasma catecholamine levels and spectral analysis of blood pressure and heart rate in dogs. Fundamental and Clinical Pharmacology 10: 298–303.

    Google Scholar 

  • Prior, P.F. (1996). The rational and utility of neurological investigations in clinical monitoring for brain and spinal cord ischaemia during surgery and intensive care. Computer methods and programs in biomedicine. 51: 13–27.

    Google Scholar 

  • Rampil, I.J. (1998). A primer for EEG signal processing in anesthesia. Anesthesiology 89: 980–1002.

    Google Scholar 

  • Schubert A., J.A. Palazzolo, J.M. Brum, M.P. Ribeiro and M. Tan (1997). Heart rate, heart rate variability, and blood pressure during perioperative stressor events in abdominal surgery. Journal of Clinical Anesthesia 9: 52–60.

    Google Scholar 

  • Todd, M.M, (1998). EEGs, EEG processing and the bispectral index. Anesthesiology. 89: 815–817.

    Google Scholar 

  • Wendling, F., G. Carrault and J.M. Badier (1997). Segmentation of Depth-EEG Seizure Signals: Method Based on a Physiological Parameter and Comparative Study. Annals of Biomedical Engineering 25: 1026–1039.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Senhadji, L., Carrault, G., Gauvrit, H. et al. Pediatric Anesthesia Monitoring with the Help of EEG and ECG. Acta Biotheor 48, 289–302 (2000). https://doi.org/10.1023/A:1010233615281

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1010233615281

Keywords

Navigation