Autoencoder for ecg signal outlier processing in system of biometric authentication

Artificial Intelligence Scientific Journal 24 (1-2):108-117 (2019)
  Copy   BIBTEX

Abstract

A novel method for ECG signal outlier processing based on autoencoder neural networks is presented in the article. Typically, heartbeats with serious waveform distortions are treated as outliers and are skipped from the authentication pipeline. The main idea of the paper is to correct these waveform distortions rather them in order to provide the system with better statistical base. During the experiments, the optimum autoencoder architecture was selected. An open Physionet ECGID database was used to verify the proposed method. The results of the studies were compared with previous studies that considered the correction of anomalies based on a statistical approach. On the one hand, the autoencoder shows slightly lower accuracy than the statistical method, but it greatly simplifies the construction of biometric identification systems, since it does not require precise tuning of hyperparameters.

Links

PhilArchive



    Upload a copy of this work     Papers currently archived: 94,045

External links

Setup an account with your affiliations in order to access resources via your University's proxy server

Through your library

Similar books and articles

Analytics

Added to PP
2021-03-27

Downloads
8 (#1,337,109)

6 months
3 (#1,209,684)

Historical graph of downloads
How can I increase my downloads?

Citations of this work

No citations found.

Add more citations

References found in this work

No references found.

Add more references